CALL 9828054276 BEFORE ORDERING FOR CORRECT SELECTION OF PUMP / AVAILABLITY
GST EXTRA 18% OR AS APPLICABLE AT THE TIME OF DELIVERY
NO WARRANTY FOR WINDING IN ANY CASE, PLEASE USE PROPER SAFTY DEVICES
Brand : ALGO
Power Supply : 220 OR415V AC Supply
Electricity Connection : SINGLE OR Three Phase
No Load Speed : 2900 RPM
Protection : IP68
Insulation Class : F Class
Head Range : 12 to 27 meters (39 to 89 feet)
Outlet Size : UP TO 4 inch (100 mm)
Max. Flow Rate : 1693 to 332 LPM
Materials of Construction :
Pump Body : Cast Iron
Impeller : High Chrome
Cutter Blade : SS
Cable : 8 mtr, H07RNF
Applications :
Waste Water treatment plant
Medical waste disposal
Industrial waste disposal
Hotels/ Dharmsahala / Resorts/ Samaroh Sthal etc.
Country of origin: India
FLOAT SWITCH SHOWN IN PHOTOS IS SUPPLIED IN 0.5 AND 1.0 HP SINGLE PHASE PUMPS ONLY, IF REQUIRED CAN BE SUPPLIED AS SEPARATE ITEM FOR OTHER MODELS OPTIONALY
NO WARRANTY FOR WINDING IN ANY CASE, PLEASE USE PROPER SAFTY DEVICES

Submersible Pump Components
Polder Submersible Pump
Horizontal Submersible Pump
Submersible Pump Sets
Submersible Pump Spare Parts
Submersible Pump Cable
Ss Fabricated Submersible Pump
Submersible Pump Coupling
Mini Submersible Pump
Submersible Pump Impeller
Pvc Submersible Pumps
UPVC Submersible Pump Pipes
In India, the installation of Effluent Treatment Plants (ETP) and Sewage Treatment Plants (STP) for hotels, resorts, and industries is governed by the Central Pollution Control Board (CPCB) under the Water Act, 1974 and Environment Protection Act, 1986.
1. Mandatory Installation Thresholds
Hotels & Resorts: Mandatory for establishments with 20 or more guest rooms or those generating significant wastewater.
Commercial Buildings: Typically required for projects with a total built-up area of 2,000 m² or more.
Industrial Units: Any industry discharging trade effluent must install an ETP regardless of its size to prevent environmental contamination.
2. Discharge Standards (CPCB Guidelines)
Treated water must meet specific chemical and physical parameters before discharge or reuse:
pH: 6.5 – 8.5 (5.5 – 9.0 for some hotel specific categories).
BOD (Biochemical Oxygen Demand): ≤ 10 mg/L (stricter for reuse) or ≤ 30 mg/L for surface water discharge.
TSS (Total Suspended Solids): ≤ 20 mg/L (metropolitan) or ≤ 50 mg/L (standard).
Oil & Grease: Must be < 10 mg/L; mandatory installation of oil/grease traps for kitchen and laundry lines.
Fecal Coliform: < 100 MPN/100 mL.
3. Compliance & Documentation
Consents: You must obtain Consent to Establish (CTE) before construction and Consent to Operate (CTO) from your respective State Pollution Control Board (SPCB) before starting operations.
Real-time Monitoring: Installations with capacity >100 KLD must install Online Continuous Effluent Monitoring Systems (OCEMS) to transmit data directly to PCB servers.
Water Audit: Regular monthly effluent quality testing by NABL-approved laboratories is required.
4. Technical Design Rules
Sizing: Use a consumption rate of 150–200 LPCD (litres per capita per day) for calculations, adding a peak factor of 1.5–2.5 to handle seasonal surges in resorts.
Segregation: Wastewater from kitchens and laundries (high chemical/oil load) should be treated in an ETP first before being mixed with domestic sewage for the STP.
Reuse: Treated water must be prioritized for non-potable uses like toilet flushing, gardening, and cooling towers.
Safety: Must include warning signage, "Do Not Drink" labels, and proper ventilation (25 air changes per hour for enclosed setups).
Are you looking for a capacity calculation for a specific number of rooms, or do you need help with the application process for a specific state?
होटल, रिसॉर्ट और इंडस्ट्री के लिए एफ्लुएंट ट्रीटमेंट प्लांट (ETPs) और सीवेज ट्रीटमेंट प्लांट (STPs) लगाना सेंट्रल पॉल्यूशन कंट्रोल बोर्ड (CPCB) देखता है।
1. ज़रूरी इंस्टॉलेशन लिमिट
होटल और रिसॉर्ट: 20 या उससे ज़्यादा गेस्ट रूम वाली जगहों या ज़्यादा गंदा पानी निकलने वाली जगहों के लिए ज़रूरी।
कमर्शियल बिल्डिंग: आम तौर पर 2,000 m2 या उससे ज़्यादा के कुल बने हुए एरिया वाले प्रोजेक्ट के लिए ज़रूरी।
इंडस्ट्रियल यूनिट: कोई भी इंडस्ट्री जो ट्रेड एफ्लुएंट निकालती है, उसे एनवायरनमेंट को खराब होने से बचाने के लिए अपने साइज़ की परवाह किए बिना ETP लगाना होगा।
2. डिस्चार्ज स्टैंडर्ड (CPCB गाइडलाइन)
ट्रीटेड पानी को डिस्चार्ज या दोबारा इस्तेमाल करने से पहले खास केमिकल और फिजिकल पैरामीटर को पूरा करना होगा:
pH: 6.5 – 8.5 (कुछ खास होटल कैटेगरी के लिए 5.5 – 9.0)।
BOD (बायोकेमिकल ऑक्सीजन डिमांड): ≤ 10 mg/L (दोबारा इस्तेमाल के लिए ज़्यादा सख्त) या सरफेस वॉटर डिस्चार्ज के लिए ≤ 30 mg/L।
TSS (टोटल सस्पेंडेड सॉलिड्स): ≤ 20 mg/L (मेट्रोपॉलिटन) या ≤ 50 mg/L (स्टैंडर्ड)।
ऑयल और ग्रीस: < 10 mg/L होना चाहिए; किचन और लॉन्ड्री लाइन के लिए ऑयल/ग्रीस ट्रैप लगाना ज़रूरी है।
फीकल कोलीफॉर्म: < 100 MPN/100 mL।
3. कंप्लायंस और डॉक्यूमेंटेशन
सहमति: आपको कंस्ट्रक्शन से पहले कंसेंट टू एस्टैब्लिश (CTE) और ऑपरेशन शुरू करने से पहले अपने स्टेट पॉल्यूशन कंट्रोल बोर्ड (SPCB) से कंसेंट टू ऑपरेट (CTO) लेना होगा।
रियल-टाइम मॉनिटरिंग: 100 KLD से ज़्यादा कैपेसिटी वाली फैसिलिटी को डेटा सीधे PCB सर्वर पर भेजने के लिए ऑनलाइन कंटीन्यूअस एफ्लुएंट मॉनिटरिंग सिस्टम (OCEMS) लगाना होगा। वॉटर ऑडिट: NABL-अप्रूव्ड लैब से रेगुलर महीने में एफ्लुएंट क्वालिटी टेस्टिंग ज़रूरी है।
4. टेक्निकल डिज़ाइन नियम
साइज़िंग: कैलकुलेशन के लिए 150–200 LPCD (लीटर प्रति व्यक्ति प्रति दिन) की खपत दर का इस्तेमाल करें, रिसॉर्ट में मौसमी बढ़ोतरी को संभालने के लिए 1.5–2.5 का पीक फैक्टर जोड़ें।
अलग करना: किचन और लॉन्ड्री से निकलने वाले गंदे पानी (ज़्यादा केमिकल/ऑयल लोड) को STP के लिए घरेलू सीवेज के साथ मिलाने से पहले ETP में ट्रीट किया जाना चाहिए।
दोबारा इस्तेमाल: ट्रीट किए गए पानी को टॉयलेट फ्लशिंग, बागवानी और कूलिंग टावर जैसे गैर-पीने लायक कामों के लिए प्राथमिकता दी जानी चाहिए।
सुरक्षा: चेतावनी के साइन, "पीना मना है" लेबल और सही वेंटिलेशन (बंद सेटअप के लिए हर घंटे 25 एयर चेंज) शामिल होना चाहिए।
क्या आप कुछ खास कमरों के लिए कैपेसिटी कैलकुलेशन ढूंढ रहे हैं, या आपको किसी खास राज्य के लिए एप्लीकेशन प्रोसेस में मदद चाहिए?

